Application: CamSafe chambers are used when filtering radioactive, toxic or bacterial particles and gasses and provide maximum safety for the operator. Areas of use include laboratories, isolation wards and the pharmaceutical industry. The casings can be joined together so that multi-stage filter systems with a volume flow of up to 24,000 m3/h can be achieved.
|
Epoxy coated casing: Epoxy resin coating in RAL 9010 which is capable of being decontaminated, clamping device made from high grade steel 1.4301.
|
Steel casing: Manufactured in high grade steel 1.4301.
|
Standard design: Material thickness 2mm, flange drilled ready for operation, service cover with male thread hand knobs, changing bag, support shelf for contact free filter changing, automative tension regulating filter clamping device.
|
Options: Filter seal seating test device in accordance with DIN 1946 Part 4, pressure compensation device and pressure check points.
|
Filter cartridges:
|
Prefilter P1: 610x610x47mm .
|
Prefilter P2: 610x610x292mm.
|
Main filter: 610x610x292mm.
|
All main filters come equipped with straps to aid the handling, enabling them to be changed easily.
|
The filters can be supplied with a variety of gaskets to suit the application.
|
The casing is suitable for different classes of filter, suitable for dealing with glasses or particle contamination.
|
Accessories: Safe change bags, manometers and material for the flanged joints supplied on request.
|